Commercial Aeroseal Duct Sealing in Central New Jersey

We help building owners and facilities teams seal air leaks inside existing HVAC ductwork. Tell us which air handler or tenant space is affected. We’ll review the duct runs, access and available work windows with you before we price the job.

Overhead ductwork serving a commercial building

Which part of the building loses air?

A row of offices at the far end of a supply run may get too little air while rooms near the air handler are comfortable. Leaks are one possible cause. A closed damper or a controls issue can produce a similar complaint. We start with the areas affected and any measurements your facilities team already has.

  • Existing occupied space. Identify the rooms served by the same unit and when the tenants can give access. One air handler may serve several separate suites.
  • A floor under renovation. Let us know which ducts will remain, what is exposed now and when ceilings are due to close.
  • A project with a leakage specification. Send the relevant drawing or specification. We’ll review the test boundary, target and required documentation before quoting.
Ceiling air outlet in a commercial interior
A ceiling outlet can be easy to reach in one suite and above a locked tenant space in the next. Both affect how a section can be isolated.

How we plan sealing around an occupied building

The section being tested needs to be taken out of normal service. We agree with the building representative on the space affected, who can authorize the shutdown and when the area can return to use.

  1. Trace and isolate

    Identify the air handler, duct section and outlets. Review ceiling and mechanical-room access, equipment protection and any area that must stay in operation.

  2. Test and seal

    A baseline test measures how much air escapes. On suitable ductwork, air carries sealant particles to small openings, where they collect around the edges. A disconnected run or large open joint needs separate attention before sealing can proceed.

  3. Retest and release

    Retest the same section, document the result and coordinate restoration with the site contact. When the building has several sections, identify each one on the drawing or equipment schedule.

What the leakage report tells you

Leakage is recorded in cubic feet of air per minute (CFM) at a stated test pressure. To compare the readings, use the same isolated duct section and the same reference pressure before and after sealing. This lets the owner or engineer see how much leakage changed within the quoted boundary.

A leakage test measures air escaping from ductwork. Airflow at a workstation or grille is a different measurement. If your closeout also requires room-by-room airflow, balancing, an independent witness or an engineer’s sign-off, identify that requirement before the bid.

For a published example of how a facilities team used section-by-section results, see Aeroseal’s Louisville Gas & Electric office-building case study.

What goes into your commercial duct sealing quote?

We quote commercial work by the duct sections to be tested and sealed. Two buildings of the same floor area can have very different prices if one system can be isolated at once and the other needs a separate visit to each tenant.

Systems and access
Number of air handlers and test sections, ceiling and mechanical-room access, and work needed to prepare the ductwork.
Scheduling
Available shutdown windows, phasing, access escorts and any request for evening or weekend work. We confirm availability and any additional charges in the proposal.
Records and handoff
Test conditions, reporting by section and any special acceptance requirements. Confirm the items included and any work assigned to another trade.
Building mechanical room with air distribution equipment
If you know the air handler ID, include it in your request. A floor plan or equipment schedule can help us match that unit to the rooms it serves.

Before you arrange site access

Can I request an estimate without mechanical drawings?

Yes. Start with the building address, spaces affected, approximate number of systems and a contact who can access the mechanical room. We’ll discuss what else we need and whether a site visit is the next step.

Can the rest of the property remain open?

That depends on which spaces share the isolated section and how access is managed. Tell us which operations must continue and when each area is available. We’ll review the boundaries and proposed work windows with the person responsible for building operations.

Will sealing address a damaged duct or blocked return?

Sealing can reduce leakage through small openings in suitable ductwork. A collapsed duct, broken connection, obstruction or control fault can require other work. We discuss prerequisites and exclusions with you before agreeing on the sealing scope.

Who can verify the contractor and service area?

Our office is in Monroe Township. You can check our New Jersey credentials and view the Central New Jersey locations we serve. For ductwork serving a single home, see residential Aeroseal duct sealing.

Request a commercial duct sealing assessment

In Service Details, include the building use, street address, rooms or floors involved and any restricted work hours. If there is a bid deadline or leakage target, include it here. Our Monroe Township office will follow up to discuss the project.

City Ventilations LLC
Monday–Friday, 8:00 a.m.–3:30 p.m. Eastern
(732) 790-2534 · hvac@cityventilations.com